Itho Daalderop Heat Pump Error Code A1 33
Code 33 means the expansion valve is already fully open and the discharge-gas temperature still stays too high relative to the liquid temperature. That pattern fits too little refrigerant in the circuit, for example due to a leak; hunting the leak is work for an F-gas certified installer.
Also shown as: A01 33
Applies to: Itho Daalderop WPU 5G and older WPU types with an MFT thermostat (shown there as A01)
Common causes
- Too little refrigerant in the circuit, for example due to a leak, forcing the expansion valve to stand fully open
- The expansion valve no longer regulates properly and cannot correct the superheat
- One of the sensors (T6 or T7) reads incorrectly, making the ratio between discharge-gas and liquid temperature look disturbed
What to check, in order
- Write down the code and check whether the home is still being heated and hot water is available.
- Open all radiator valves and underfloor-heating groups, bleed the heating system and reset the unit once.
- If the code returns, call an installer with F-gas certification and quote the code; the circuit must be checked for leaks and the pressures measured.
Clear the code and test
- Fix what the checks above found first — a filter cleaned, a setting corrected, power restored. Clearing the code without fixing the cause only brings it back.
- Make sure the heat pump has power and the controller is set to heating or hot water, as you need it.
- Restart the unit as your manual describes and give it time: a heat pump can take ten to twenty minutes to start a full cycle.
- If the unit runs a full cycle with no code, the fault is cleared. If the code returns, write down the code and what the unit was doing (heating, hot water or defrosting) before calling a technician — it speeds up the diagnosis.
When to call a professional
This code usually points to a faulty part, wiring or the control board on a Itho Daalderop heat pump. Run the checks above to rule out the simple causes, then book a technician — and book one straight away if any of these apply:
- The code comes back after you have run the checks and a test cycle.
- You smell burning, see sparks or scorch marks, or the breaker trips.
- Water is leaking and you cannot stop it.
- The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.
When you call, give the brand, the code A1 33, your model number (on a label on the type plate, usually on the side of the unit) and the checks you already ran. It shortens the visit.
Repair or replace?
This fault is in professional territory: the fix usually means a major part or board-level work, and the labour adds up. If your machine is already well into its service life, get the repair quote first, then compare it with the price of a current equivalent model before you decide. Paying a large share of a new machine's price to repair an old one is rarely the better deal; replacing a machine over one cheap fault is wasteful too.
Parts that may be involved
Expansion valveTemperature sensor T6 (discharge gas)Temperature sensor T7 (liquid)
Parts are model-specific. Find your model number first — usually on a label on the type plate, usually on the side of the unit — and match the part to that number before ordering.
Questions people ask about A1 33
What does A1 33 mean on a Itho Daalderop heat pump?
A1 33 means: The discharge-gas temperature is too high relative to the liquid temperature and the expansion valve is fully open. Code 33 means the expansion valve is already fully open and the discharge-gas temperature still stays too high relative to the liquid temperature. That pattern fits too little refrigerant in the circuit, for example due to a leak; hunting the leak is work for an F-gas certified installer.
Can I fix Itho Daalderop A1 33 myself?
Only the preliminary checks. Code A1 33 usually means a part, wiring or the control board has failed, which is a technician job. Run the checks to rule out simple causes before you book.
How do I clear Itho Daalderop A1 33?
Fix what the checks above found first — a filter cleaned, a setting corrected, power restored. Clearing the code without fixing the cause only brings it back. Make sure the heat pump has power and the controller is set to heating or hot water, as you need it. Restart the unit as your manual describes and give it time: a heat pump can take ten to twenty minutes to start a full cycle.
Sources checked
- Itho Daalderop WPU 5G user manual (manufacturer document)
- Itho Daalderop service chapter: WPU 5G faults (JK Engineered Solutions)